Review



immunomagnetic negative selection kit easysep human naïve cd4 + t cell separation kit ii  (STEMCELL Technologies Inc)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    STEMCELL Technologies Inc immunomagnetic negative selection kit easysep human naïve cd4 + t cell separation kit ii
    Immunomagnetic Negative Selection Kit Easysep Human Naïve Cd4 + T Cell Separation Kit Ii, supplied by STEMCELL Technologies Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/immunomagnetic+cell+separation+kits+human+cd4++negative+selection+kit/immunomagnetic+negative+selection+kit+easysep+human+cd4+++t+cells+enrichment+kit/pmc09478378-122-10-24
    Average 90 stars, based on 1 article reviews
    immunomagnetic negative selection kit easysep human naïve cd4 + t cell separation kit ii - by Bioz Stars, 2026-10
    90/100 stars

    Images

    Related Articles

    other:

    Article Title: Granzyme B + CD4 T cells accumulate in the colon during chronic HIV-1 infection
    Article Snippet: LP CD4 T cells were isolated from the total LPMC using immunomagnetic negative selection (EasySep Human CD4 + T cell isolation kit; Stemcell Technologies) according to the manufacturer’s instructions.

    Article Title: DNA Hypomethylation in the TNF-Alpha Gene Predicts Rheumatoid Arthritis Classification in Patients with Early Inflammatory Symptoms.
    Article Snippet: CD4+ T-cells were isolated from frozen PBMC using immunomagnetic negative selection (EasySep Human CD4+ T Cell Isolation Kit (STEMCELL Technologies, Cambridge, UK) according to protocol).

    Article Title: NAMPT is a metabolic checkpoint of IFNγ-producing CD4 + T cells in lupus nephritis.
    Article Snippet: Correspondence:Hui Zhang, MD, PhD, Department of Rheumatology, Institute of Precision Medicine, The First Affiliated Hospital, Sun Yat-sen University, 58 Zhongshan Second Road, Guangzhou, China.. E-mail: zhangh656@mail.sysu.edu.cn Interferon g (IFNg) produced by T cells represents the featured cytokine and is central to the pathogenesis of lupus nephritis (LN).. Here, we identified nicotinamide phosphoribosyltransferase (NAMPT), the rate-limiting enzyme in the salvage NAD biosynthetic pathway, as playing a key role in controlling IFNg production by CD4 T cells in LN.

    Article Title: Increased DNA methylation of SLFN12 in CD4+ and CD8+ T cells from multiple sclerosis patients.
    Article Snippet: For the Norwegian samples, CD4+ and CD8+ T cells were isolated from freshly collected peripheral blood mononuclear cells (PBMCs) using immunomagnetic cell separation selection kits (EasySep Human CD4+ T cell Isolation Kit (negative selection) and EasySep Human CD8+ Selection Kit (positive selection), StemCell Technologies, Canada) according to the manufacturer instructions.

    Isolation:

    Article Title: Increased DNA methylation of SLFN12 in CD4 + and CD8 + T cells from multiple sclerosis patients
    Article Snippet: .. For the Norwegian samples, CD4 + and CD8 + T cells were isolated from freshly collected peripheral blood mononuclear cells (PBMCs) using immunomagnetic cell separation selection kits (EasySep Human CD4 + T cell Isolation Kit (negative selection) and EasySep Human CD8 + Selection Kit (positive selection), StemCell Technologies, Canada) according to the manufacturer instructions. .. Purified cells were stained with FITC-conjugated mouse anti-human CD4 (clone RFT4, catalog #9522–02, Southern Biotech, USA) or FITC-conjugated mouse anti-human CD8 (clone HIT8a, catalog #555634, BD Biosciences, USA) and FITC-conjugated mouse IgG1 isotype control (clone 15H6, catalog #0102–02, Southern Biotech, USA) antibodies, and purity exceeding 95% was confirmed by flow cytometry (Attune Acoustic Focusing Cytometer, Applied Biosystems, USA).

    Selection:

    Article Title: Increased DNA methylation of SLFN12 in CD4 + and CD8 + T cells from multiple sclerosis patients
    Article Snippet: .. For the Norwegian samples, CD4 + and CD8 + T cells were isolated from freshly collected peripheral blood mononuclear cells (PBMCs) using immunomagnetic cell separation selection kits (EasySep Human CD4 + T cell Isolation Kit (negative selection) and EasySep Human CD8 + Selection Kit (positive selection), StemCell Technologies, Canada) according to the manufacturer instructions. .. Purified cells were stained with FITC-conjugated mouse anti-human CD4 (clone RFT4, catalog #9522–02, Southern Biotech, USA) or FITC-conjugated mouse anti-human CD8 (clone HIT8a, catalog #555634, BD Biosciences, USA) and FITC-conjugated mouse IgG1 isotype control (clone 15H6, catalog #0102–02, Southern Biotech, USA) antibodies, and purity exceeding 95% was confirmed by flow cytometry (Attune Acoustic Focusing Cytometer, Applied Biosystems, USA).

    Article Title: Global DNA methylation changes in treated and untreated MS patients measured over time.
    Article Snippet: .. Purification of CD4+ and CD8+ T cells CD4+ and CD8+ T cells were purified using immunomagnetic cell separation kits (Human CD4+ negative selection kit and EasySepTM Human CD8+ positive selection kit and EasySepTM, STEMCELL Technologies, Vancouver, Canada) as described in (Rhead et al., 2018; Bos et al., 2015). .. Purity of isolated T cells was confirmed to be at least 95% as measured by flow cytometry (Attune Acoustic Focusing Flow Cytometer, Life Technologies, Carlsbad, CA, USA).

    Article Title: The Th1/Tfh-like biased responses elicited by the rASP-1 innate adjuvant are dependent on TRIF and Type I IFN receptor pathways
    Article Snippet: Data were acquired using a Fortessa X-20 (BD Biosciences) and analyzed with FlowJo software (BD Biosciences) .. Naïve CD4 + T cells were purified from PBMCs using immunomagnetic negative selection kit (EasySep Human Naïve CD4 + T cell separation kit II, StemCell Technologies); cell purity was >98%. ..

    Cell Isolation:

    Article Title: Increased DNA methylation of SLFN12 in CD4 + and CD8 + T cells from multiple sclerosis patients
    Article Snippet: .. For the Norwegian samples, CD4 + and CD8 + T cells were isolated from freshly collected peripheral blood mononuclear cells (PBMCs) using immunomagnetic cell separation selection kits (EasySep Human CD4 + T cell Isolation Kit (negative selection) and EasySep Human CD8 + Selection Kit (positive selection), StemCell Technologies, Canada) according to the manufacturer instructions. .. Purified cells were stained with FITC-conjugated mouse anti-human CD4 (clone RFT4, catalog #9522–02, Southern Biotech, USA) or FITC-conjugated mouse anti-human CD8 (clone HIT8a, catalog #555634, BD Biosciences, USA) and FITC-conjugated mouse IgG1 isotype control (clone 15H6, catalog #0102–02, Southern Biotech, USA) antibodies, and purity exceeding 95% was confirmed by flow cytometry (Attune Acoustic Focusing Cytometer, Applied Biosystems, USA).

    Purification:

    Article Title: Global DNA methylation changes in treated and untreated MS patients measured over time.
    Article Snippet: .. Purification of CD4+ and CD8+ T cells CD4+ and CD8+ T cells were purified using immunomagnetic cell separation kits (Human CD4+ negative selection kit and EasySepTM Human CD8+ positive selection kit and EasySepTM, STEMCELL Technologies, Vancouver, Canada) as described in (Rhead et al., 2018; Bos et al., 2015). .. Purity of isolated T cells was confirmed to be at least 95% as measured by flow cytometry (Attune Acoustic Focusing Flow Cytometer, Life Technologies, Carlsbad, CA, USA).

    Article Title: The Th1/Tfh-like biased responses elicited by the rASP-1 innate adjuvant are dependent on TRIF and Type I IFN receptor pathways
    Article Snippet: Data were acquired using a Fortessa X-20 (BD Biosciences) and analyzed with FlowJo software (BD Biosciences) .. Naïve CD4 + T cells were purified from PBMCs using immunomagnetic negative selection kit (EasySep Human Naïve CD4 + T cell separation kit II, StemCell Technologies); cell purity was >98%. ..



    Similar Products

    97
    Miltenyi Biotec immunomagnetic negative selection based separation
    Figure 2. Comparison of viability and purity after the different <t>separation</t> techniques. Viability was determined with 7-AAD staining while purity was expressed as a percentage of <t>CD4+</t> cells in the living cell population (see Methods). Measurements were made via flow cytometry, subsequently after the separation (values are plotted as mean±SD for the number of independent experiments indicated in the bar). No significant differences were found among the groups for either viability or purity (one-way analysis of variance, p > 0.05). REAlease®: measured after the complete removal of bead-antibody and REAlease® complex, in label-free configuration (see Figure 1), Negative selection: <t>immunomagnetic</t> negative selection, Sorted: positive selection by flow cytometry.
    Immunomagnetic Negative Selection Based Separation, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/immunomagnetic+cell+separation+kits+human+cd4++negative+selection+kit/CD4%2B+T+Cell+Isolation+Kit%2C+human/pm33356811-55-0-12
    Average 97 stars, based on 1 article reviews
    immunomagnetic negative selection based separation - by Bioz Stars, 2026-10
    97/100 stars
      Buy from Supplier

    90
    STEMCELL Technologies Inc immunomagnetic negative selection kit easysep human naïve cd4 + t cell separation kit ii
    Figure 2. Comparison of viability and purity after the different <t>separation</t> techniques. Viability was determined with 7-AAD staining while purity was expressed as a percentage of <t>CD4+</t> cells in the living cell population (see Methods). Measurements were made via flow cytometry, subsequently after the separation (values are plotted as mean±SD for the number of independent experiments indicated in the bar). No significant differences were found among the groups for either viability or purity (one-way analysis of variance, p > 0.05). REAlease®: measured after the complete removal of bead-antibody and REAlease® complex, in label-free configuration (see Figure 1), Negative selection: <t>immunomagnetic</t> negative selection, Sorted: positive selection by flow cytometry.
    Immunomagnetic Negative Selection Kit Easysep Human Naïve Cd4 + T Cell Separation Kit Ii, supplied by STEMCELL Technologies Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/immunomagnetic+cell+separation+kits+human+cd4++negative+selection+kit/immunomagnetic+negative+selection+kit+easysep+human+cd4+++t+cells+enrichment+kit/pmc09478378-122-10-24
    Average 90 stars, based on 1 article reviews
    immunomagnetic negative selection kit easysep human naïve cd4 + t cell separation kit ii - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    STEMCELL Technologies Inc immunomagnetic cell separation kits human cd4+ negative selection kit
    Figure 2. Comparison of viability and purity after the different <t>separation</t> techniques. Viability was determined with 7-AAD staining while purity was expressed as a percentage of <t>CD4+</t> cells in the living cell population (see Methods). Measurements were made via flow cytometry, subsequently after the separation (values are plotted as mean±SD for the number of independent experiments indicated in the bar). No significant differences were found among the groups for either viability or purity (one-way analysis of variance, p > 0.05). REAlease®: measured after the complete removal of bead-antibody and REAlease® complex, in label-free configuration (see Figure 1), Negative selection: <t>immunomagnetic</t> negative selection, Sorted: positive selection by flow cytometry.
    Immunomagnetic Cell Separation Kits Human Cd4+ Negative Selection Kit, supplied by STEMCELL Technologies Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/immunomagnetic+cell+separation+kits+human+cd4++negative+selection+kit/immunomagnetic+negative+selection+kit+easysep+human+cd4+++t+cells+enrichment+kit/pm35093762-41-15-33
    Average 90 stars, based on 1 article reviews
    immunomagnetic cell separation kits human cd4+ negative selection kit - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    Image Search Results


    Figure 2. Comparison of viability and purity after the different separation techniques. Viability was determined with 7-AAD staining while purity was expressed as a percentage of CD4+ cells in the living cell population (see Methods). Measurements were made via flow cytometry, subsequently after the separation (values are plotted as mean±SD for the number of independent experiments indicated in the bar). No significant differences were found among the groups for either viability or purity (one-way analysis of variance, p > 0.05). REAlease®: measured after the complete removal of bead-antibody and REAlease® complex, in label-free configuration (see Figure 1), Negative selection: immunomagnetic negative selection, Sorted: positive selection by flow cytometry.

    Journal: Channels (Austin, Tex.)

    Article Title: Immunomagnetic separation is a suitable method for electrophysiology and ion channel pharmacology studies on T cells.

    doi: 10.1080/19336950.2020.1859753

    Figure Lengend Snippet: Figure 2. Comparison of viability and purity after the different separation techniques. Viability was determined with 7-AAD staining while purity was expressed as a percentage of CD4+ cells in the living cell population (see Methods). Measurements were made via flow cytometry, subsequently after the separation (values are plotted as mean±SD for the number of independent experiments indicated in the bar). No significant differences were found among the groups for either viability or purity (one-way analysis of variance, p > 0.05). REAlease®: measured after the complete removal of bead-antibody and REAlease® complex, in label-free configuration (see Figure 1), Negative selection: immunomagnetic negative selection, Sorted: positive selection by flow cytometry.

    Article Snippet: Immunomagnetic negative selection-based separation (CD4+ T Cell Isolation Kit Cat. No.: 130–096-533 Miltenyi Biotec B.V. & Co. KG, Bergisch Gladbach, Germany) was prepared to isolate cells without labeling of the CD4 molecule, and these cells served as the “Control” configuration (Figure 1).

    Techniques: Comparison, Staining, Flow Cytometry, Selection